892 research outputs found

    Physics-based large-signal sensitivity analysis of microwave circuits using technological parametric sensitivity from multidimensional semiconductor device models

    Get PDF
    The authors present an efficient approach to evaluate the large-signal (LS) parametric sensitivity of active semiconductor devices under quasi-periodic operation through accurate, multidimensional physics-based models. The proposed technique exploits efficient intermediate mathematical models to perform the link between physics-based analysis and circuit-oriented simulations, and only requires the evaluation of dc and ac small-signal (dc charge) sensitivities under general quasi-static conditions. To illustrate the technique, the authors discuss examples of sensitivity evaluation, statistical analysis, and doping profile optimization of an implanted MESFET to minimize intermodulation which makes use of LS parametric sensitivities under two-tone excitatio

    Hemodynamic evaluation using four-dimensional flow magnetic resonance imaging for a patient with multichanneled aortic dissection

    Get PDF
    The hemodynamic function of multichanneled aortic dissection (MCAD) requires close monitoring and effective management to avoid potentially catastrophic sequelae. This report describes a 47-year-old man who underwent endovascular repair based on findings from four-dimensional (4D) flow magnetic resonance imaging of an MCAD. The acquired 4D flow data revealed complex, bidirectional flow patterns in the false lumens and accelerated blood flow in the compressed true lumen. The collapsed abdominal true lumen expanded unsatisfactorily after primary tear repair, which required further remodeling with bare stents. This case study demonstrates that hemodynamic analysis using 4D flow magnetic resonance imaging can help understand the complex pathologic changes of MCAD

    Dynamic, self consistent electro-thermal simulation of power microwave devices including the effect of surface metallizations

    Get PDF
    We present an efficient simulation technique to account for the thermal spreading effects of surface metallizations in the self-consistent dynamic electro-thermal analysis of power microwave devices. Electro-thermal self-consistency is achieved by solving the coupled nonlinear system made of a temperature dependent device electrical model, and of an approximate description of the device thermal behavior through a thermal impedance matrix. The numerical solution is pursued in the frequency domain by the Harmonic Balance technique. The approach is applied to the thermal stability analysis of power AlGaAs/GaAs HBTs and the results show that metallizations have a significant impact on the occurrence of the device thermal collapse

    Studying oven technology towards the energy consumption optimisation for the baking process

    Get PDF
    A recent guideline from the European Commission declared that several highly energy consuming domestic equipment should be better regulated or avoided at all in the near future. Together with this, several EU nations are abandoning the gas ovens in favour of the electric ones, also due to the home energy rating regulations, that make impossible to get the highest rating with gas ovens. Due to this fact, the study of the technologies related to the energy efficiency in cooking is increasingly developing. The combination of several energy sources (e.g. forced convection, irradiation, microwave, etc.), as well as optimisation of each of them, is an emerging target for oven manufacturers, in matter of oven design and better use of the oven capabilities. Within this context, an energy consumption analysis and optimisation is targeted in this work, by the application of a bread baking model, validated on experimental data. Each source of energy is given the due importance and the practically applicable process solutions are compared. A basic quality standard is guaranteed by taking into account some quality markers, which are relevant on the basis of a consumer point of view. This work is a part of a more comprehensive study on oven cooking and energy integration, and could lead to practical applications in the design of energy efficient cooking programs

    Analysis of a possible application of a new process for oxygen enriched air production

    Get PDF
    A new process for oxygen enriched air (EA) production has been applied to Claus Process. This process is simple and requires few process units. Matlab and Aspen Hysys have been used for simulations and system sizing. The results demonstrate that it could be an alternative to traditional EA processes from an economical point of view

    Aortic haemodynamics and wall stress analysis following arch aneurysm repair using a single-branched endograft

    Get PDF
    Introduction: Thoracic endovascular aortic repair (TEVAR) of the arch is challenging given its complex geometry and the involvement of supra-aortic arteries. Different branched endografts have been designed for use in this region, but their haemodynamic performance and the risk for post-intervention complications are not yet clear. This study aims to examine aortic haemodynamics and biomechanical conditions following TVAR treatment of an aortic arch aneurysm with a two-component single-branched endograft. Methods: Computational fluid dynamics and finite element analysis were applied to a patient-specific case at different stages: pre-intervention, post-intervention and follow-up. Physiologically accurate boundary conditions were used based on available clinical information. Results: Computational results obtained from the post-intervention model confirmed technical success of the procedure in restoring normal flow to the arch. Simulations of the follow-up model, where boundary conditions were modified to reflect change in supra-aortic vessel perfusion observed on the follow-up scan, predicted normal flow patterns but high levels of wall stress (up to 1.3M MPa) and increased displacement forces in regions at risk of compromising device stability. This might have contributed to the suspected endoleaks or device migration identified at the final follow up. Discussion: Our study demonstrated that detailed haemodynamic and biomechanical analysis can help identify possible causes for post-TEVAR complications in a patient-specific setting. Further refinement and validation of the computational workflow will allow personalised assessment to aid in surgical planning and clinical decision making

    Perfluoropolyethers coatings design for fouling reduction on heat transfer stainless steel surfaces

    Get PDF
    The scope of this research is to obtain a film coating on stainless steel surfaces in order to reduce the interaction between the metal surface and the precipitates, so to mitigate fouling in heat exchangers. Perfuoropolyethers were used to obtain nano-range fluorinated layers in order to make hydrophobic the stainless steel surfaces. A pilot plant with two identical heat exchangers was built to investigate the ability of the hydrophobic coating of preventing fouling. The heat exchangers, installed in parallel, operated at the same temperature and pressure conditions, i.e. laminar flow regime and inlet flow temperatures of 291\u2013293 K for cold streams and 313\u2013333 K for hot streams. We compared the heat transfer performance of the two heat exchangers. After a five months operation the decrease in the heat transferred was 56% for the coated heat exchanger and 62% for the uncoated heat exchanger. Moreover, the increase of heat transfer resistance due to scale on the uncoated heat exchanger, with respect to the coated one, was three times higher

    Analysis of turbulence effects in a patient-specific aorta with aortic valve stenosis

    Get PDF
    Blood flow in the aorta is often assumed laminar, however aortic valve pathologies may induce transition to turbulence and our understanding of turbulence effects is incomplete. The aim of the study was to provide a detailed analysis of turbulence effects in aortic valve stenosis (AVS). Methods: Large-eddy simulation (LES) of flow through a patient-specific aorta with AVS was conducted. Magnetic resonance imaging (MRI) was performed and used for geometric reconstruction and patient-specific boundary conditions. Computed velocity field was compared with 4D flow MRI to check qualitative and quantitative consistency. The effect of turbulence was evaluated in terms of fluctuating kinetic energy, turbulence-related wall shear stress (WSS) and energy loss. Results: Our analysis suggested that turbulence was induced by a combination of a high velocity jet impinging on the arterial wall and a dilated ascending aorta which provided sufficient space for turbulence to develop. Turbulent WSS contributed to 40% of the total WSS in the ascending aorta and 38% in the entire aorta. Viscous and turbulent irreversible energy losses accounted for 3.9 and 2.7% of the total stroke work, respectively. Conclusions: This study demonstrates the importance of turbulence in assessing aortic haemodynamics in a patient with AVS. Neglecting the turbulent contribution to WSS could potentially result in a significant underestimation of the total WSS. Further work is warranted to extend the analysis to more AVS cases and patients with other aortic valve diseases
    • 

    corecore